Notice: Function Pods Templates was called incorrectly. Pod Template PHP code is no longer actively supported and will be completely removed in Pods 3.3 Please see Debugging in WordPress for more information. (This message was added in version 3.0.) in /var/www/html/wp-includes/functions.php on line 6085
Deprecated: Pod Template PHP code has been deprecated, please use WP Templates instead of embedding PHP. has been deprecated since Pods version 2.3 with no alternative available. in /var/www/html/wp-content/plugins/pods/includes/general.php on line 1037
QIN PROSTATE | QIN PROSTATE
DOI: 10.7937/K9/TCIA.2016.fADs26kG | Data Citation Required | Image Collection
Location | Species | Subjects | Data Types | Cancer Types | Size | Status | Updated |
---|---|---|---|---|---|---|---|
Prostate | Human | 22 | MR | Prostate Cancer | Limited, Complete | 2014/07/02 |
Summary
This collection contains multiparametric MRI images collected for the purposes of detection and/or staging of prostate cancer. The MRI parameters include T1- and T2-weighted sequences as well as Diffusion Weighted and Dynamic Contrast-Enhanced MRI. The images were obtained using endorectal and phased array surface coils at 3.0T (GE Signa HDx 15.0) The value of this collection is to provide clinical image data for the development and evaluation of quantitative methods for prostate cancer characterization using multiparametric MRI. Data was provided by Brigham and Women's Hospital, PI Dr. Fiona Fennessy.MR imaging exam was performed on a GE Signa HDx 3.0 T magnet (GE Healthcare, Waukesha, WI) using a combination of 8-channel abdominal array and endorectal coil (Medrad, Pittsburgh, PA). The MR sequences included T1- and T2-weighted imaging, diffusion weighted (DW) imaging, and DCE MRI. T1-weighted imaging was performed with a spoiled gradient recalled echo (SPGR) sequence with TR/TE/α = 385 ms/6.2 ms/65° over a (16 cm)2 field of view (FOV). T2-weighted imaging was performed with a FRFSE (Fast Recovery Fast Spin Echo) sequence with TR/TE = 3500/102 ms, FOV = (16 cm)2. A DW echo planar imaging sequence with trace diffusion sensitization and b-values of 0 and 500 s/mm2, and TR/TE = 2500/65 ms provided data for an Apparent Diffusion Coefficient (ADC) map. Finally, DCE MRI utilized a 3D SPGR sequence with TR/TE/α = 3.6 ms/1.3 ms/15°, FOV = (26 cm)2, with full gland coverage and reconstructed image voxel size of 1×1×6 mm (interpolated to 256×256 matrix). DCE MRI frames were acquired at approximately 5 s intervals (the number of frames varied between 12 and 16 slices resulting in the time resolution between 4.4 and 5.3 seconds) to achieve a clinically appropriate compromise between spatial and temporal resolutions. Gadopentetate dimeglumine (Magnevist, Berlex Laboratories, Wayne, New Jersey) was injected intravenously using a syringe pump (0.15 mmol/kg) at the rate of 3 ml/s followed by 20 ml saline flush at the same rate. The protocol included ~ 5 baseline scans prior to contrast injection for estimation of baseline tissue properties. The mission of the QIN is to improve the role of quantitative imaging for clinical decision making in oncology by developing and validating data acquisition, analysis methods, and tools to tailor treatment for individual patients and predict or monitor the response to drug or radiation therapy. More information is available on the Quantitative Imaging Network Collections page. Interested investigators can apply to the QIN at: Quantitative Imaging for Evaluation of Responses to Cancer Therapies (U01) PAR-11-150.About the NCI QIN
Data Access
When you have a TCIA account, please email to help@cancerimagingarchive.net to request access to these data.
Version 1: Updated 2014/07/02
Title | Data Type | Format | Access Points | Subjects | License | |||
---|---|---|---|---|---|---|---|---|
Images | MR | DICOM | Download requires NBIA Data Retriever |
22 | 22 | 319 | 25,981 | TCIA Limited (contact Support) |
Citations & Data Usage Policy
Data Citation Required: Users must abide by the TCIA Data Usage Policy and Restrictions. Attribution must include the following citation, including the Digital Object Identifier:
Data Citation |
|
Fedorov A, Tempany C, Mulkern R, & Fennessy F. (2016). Data From QIN PROSTATE. The Cancer Imaging Archive. DOI: 10.7937/K9/TCIA.2016.fADs26kG |
Detailed Description
A subset of datasets from this collection were used in [1]. The MR sequences included T1– and T2-weighted imaging, diffusion weighted (DW) imaging, and DCE MRI following the protocol described in [2].
References
[1] Fedorov, A., Fluckiger, J., Ayers, G. D., Li, X., Gupta, S. N., Tempany, C., Mulkern, R., Yankeelov, T.E., Fennessy, F. M. (2014). A comparison of two methods for estimating DCE-MRI parameters via individual and cohort based AIFs in prostate cancer: A step towards practical implementation. Magnetic Resonance Imaging, 32(4), 321–9. doi:10.1016/j.mri.2014.01.004
[2] Hegde, J. V, Mulkern, R. V, Panych, L. P., Fennessy, F. M., Fedorov, A., Maier, S. E., & Tempany, C. M. C. (2013). Multiparametric MRI of prostate cancer: An update on state-of-the-art techniques and their performance in detecting and localizing prostate cancer. Journal of Magnetic Resonance Imaging : JMRI, 37(5), 1035–54. doi:10.1002/jmri.23860
Related Publications
Publications by the Dataset Authors
The authors recommended this paper as the best source of additional information about this dataset:
Fedorov A, Fluckiger J, Ayers GD, Li X, Gupta SN, Tempany C, Mulkernag R, Yankeelov TE, Fennessy FM. (2014). A comparison of two methods for estimating DCE-MRI parameters via individual and cohort based AIFs in prostate cancer: A step towards practical implementation. Magnetic Resonance Imaging 32(4):321-329. DOI: 10.1016/j.mri.2014.01.004
Hegde, J. V., Mulkern, R. V., Panych, L. P., Fennessy, F. M., Fedorov, A., Maier, S. E., & Tempany, C. M. C. (2013, April 18). Multiparametric MRI of prostate cancer: An update on state-of-the-art techniques and their performance in detecting and localizing prostate cancer. J. Magn. Reson. Imaging. Wiley-Blackwell. http://doi.org/10.1002/jmri.23860