Notice: Function Pods Templates was called incorrectly. Pod Template PHP code is no longer actively supported and will be completely removed in Pods 3.3 Please see Debugging in WordPress for more information. (This message was added in version 3.0.) in /var/www/html/wp-includes/functions.php on line 6085
Deprecated: Pod Template PHP code has been deprecated, please use WP Templates instead of embedding PHP. has been deprecated since Pods version 2.3 with no alternative available. in /var/www/html/wp-content/plugins/pods/includes/general.php on line 1037
DICOM-SR-Breast-Clinical | DICOM SR of clinical data and measurement for breast cancer collections to TCIA
DOI: 10.7937/TCIA.2019.wgllssg1 | Data Citation Required | Analysis Result
Location | Subjects | Size | Updated | |||
---|---|---|---|---|---|---|
Breast Cancer | Breast | 474 | DICOM SR descriptions of patient characteristics, Histopathology, receptor status and clinical findings including measurements. | 2020/05/26 |
Summary
The Data Integration & Imaging Informatics (DI-Cubed) project explored the issue of lack of standardized data capture at the point of data creation, as reflected in the non-image data accompanying various TCIA breast cancer collections. The work addressed the desire for semantic interoperability between various NCI initiatives by aligning on common clinical metadata elements and supporting use cases that connect clinical, imaging, and genomics data. Accordingly, clinical and measurement data was imported into I2B2 and cross-mapped to industry standard concepts for names and values including those derived from BRIDG, CDISC SDTM, DICOM Structured Reporting models and using NCI Thesaurus, SNOMED CT and LOINC controlled terminology. A subset of the standardized data was then exported from I2B2 to CSV and thence converted to DICOM SR according to the the DICOM Breast Imaging Report template [1] , which supports description of patient characteristics, histopathology, receptor status and clinical findings including measurements. The purpose was not to advocate DICOM SR as an appropriate format for interchange or storage of such information for query purposes, but rather to demonstrate that use of standard concepts harmonized across multiple collections could be transformed into an existing standard report representation. The DICOM SR can be stored and used together with the images in repositories such as TCIA and in image viewers that support rendering of DICOM SR content. During the project, various deficiencies in the DICOM Breast Imaging Report template were identified with respect to describing breast MR studies, laterality of findings versus procedures, more recently developed receptor types, and patient characteristics and status. These were addressed via DICOM CP 1838, finalized in Jan 2019, and this subset reflects those changes. DICOM Breast Imaging Report Templates available from: http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_BreastImagingReportTemplates.html
Data Access
Version 1: Updated 2020/05/26
Title | Data Type | Format | Access Points | Subjects | License | |||
---|---|---|---|---|---|---|---|---|
Combined SR across 4 collections | SR | DICOM | Download requires NBIA Data Retriever |
474 | 1,285 | 1,291 | 1,291 | CC BY 3.0 |
SR for TCGA-BRCA | SR | DICOM | Download requires NBIA Data Retriever |
139 | 164 | 164 | 164 | CC BY 3.0 |
SR for ISPY1 | SR | DICOM | Download requires NBIA Data Retriever |
221 | 845 | 845 | 845 | CC BY 3.0 |
SR for BREAST-DIAGNOSIS | SR | DICOM | Download requires NBIA Data Retriever |
50 | 88 | 94 | 94 | CC BY 3.0 |
SR for Breast-MRI-NACT-Pilot | SR | DICOM | Download requires NBIA Data Retriever |
64 | 189 | 189 | 189 | CC BY 3.0 |
Collections Used In This Analysis Result
Title | Data Type | Format | Access Points | Subjects | License | |||
---|---|---|---|---|---|---|---|---|
TCGA-BRCA Images | MG, MR | DICOM | Requires NBIA Data Retriever |
139 | 164 | 1,877 | 230,167 | CC BY 3.0 |
BREAST-DIAGNOSIS Images | MG, CT, MR, PT | DICOM | Requires NBIA Data Retriever |
88 | 148 | 429 | 105,050 | CC BY 3.0 |
ISPY1 Images and Segmentations | SEG, MR | DICOM | Requires NBIA Data Retriever |
222 | 847 | 9,032 | 387,680 | CC BY 3.0 |
Breast-MRI-NACT-Pilot Images and Segmentations | SEG, MR | DICOM | Requires NBIA Data Retriever |
64 | 189 | 2,224 | 98,936 | CC BY 3.0 |
Citations & Data Usage Policy
Data Citation Required: Users must abide by the TCIA Data Usage Policy and Restrictions. Attribution must include the following citation, including the Digital Object Identifier:
Data Citation |
|
Clunie D., Hickman H., Ver Hoef W., Hastak S., Wagner U., Helton E. (2019). DICOM SR of clinical data and measurement for breast cancer collections to TCIA [Data set]. The Cancer Imaging Archive. https://doi.org/10.7937/TCIA.2019.wgllssg1 |
Detailed Description
You can download all results at once through (Combined SR across 4 collections (DICOM, 1292 files, 10.0 Mb) (note, no pixel data in SR)) or in chunks:
- SR for TCGA-BRCA – 164 files 1.2Mb
- SR for ISPY1 – 845 files , 6.6Mb
- SR for BREAST-DIAGNOSIS – 94 files, 750kB
- SR for Breast-MRI-NACT-Pilot – 189 files, 1.4Mb
Related Publications
Publications by the Dataset Authors
No publications by dataset authors were found.
Publication Citation |
|
Clunie, D., Hickman, H., Ver Hoef, W., Hastak, S., Evans, J., Neville, J., & Wagner, U. (2020). Observations from the Data Integration and Imaging Informatics (DI-Cubed) Project. MDPI AG. https://doi.org/10.20944/preprints202008.0474.v1 |
Research Community Publications
TCIA maintains a list of publications that leverage TCIA data. If you have a manuscript you’d like to add please contact the TCIA Helpdesk.