Notice: Function Pods Templates was called incorrectly. Pod Template PHP code is no longer actively supported and will be completely removed in Pods 3.3 Please see Debugging in WordPress for more information. (This message was added in version 3.0.) in /var/www/html/wp-includes/functions.php on line 6085
Deprecated: Pod Template PHP code has been deprecated, please use WP Templates instead of embedding PHP. has been deprecated since Pods version 2.3 with no alternative available. in /var/www/html/wp-content/plugins/pods/includes/general.php on line 1037
BREAST-DIAGNOSIS | BREAST-DIAGNOSIS
DOI: 10.7937/K9/TCIA.2015.SDNRQXXR | Data Citation Required | Image Collection
Location | Species | Subjects | Data Types | Cancer Types | Size | Status | Updated | |
---|---|---|---|---|---|---|---|---|
Breast | Human | 88 | MG, CT, MR, PT | Breast Cancer | Clinical, Image Analyses | Public, Complete | 2011/11/09 |
Summary
The Breast-Diagnosis collection contains cases that are high-risk normals, DCIS, fibroids and lobular carcinomas. Each case has 3 or more distinct MR pulse sequences from a Phillips 1.5 T (usual sequences are labeled T2, STIR and BLISS but may occasionally include other pulse sequences and digital mammogram of tumor specimen). Multiple time point studies on the same patient are possible. The following is relevant to analyzing the contrast dynamics of the BLISS pulse sequences. The pulse sequence parameters (repetition, echo time, etc.) can be extracted from the DICOM tags. The contrast aspects are as follows: The volume of Magnevist (Bayer) gadolinium contrast injected into the brachial vein is based on a rule of thumb which in ml's is 10% of the patient weight in POUNDS (NOT kilograms as is recorded in the DICOM patient weight tag. Hence the injected volume for a 150 lb patient is 15 ml. (the DICOM tag entry on that patient will read "68"). The injection itself is 6 or 7 seconds, at a rate of 3cc per second. The first dynamic sequence is started 1 minute after the injection is started. Slice and pulse parameters are accessible in the DICOM tags. This collection also includes a spreadsheet (updated 7/16/11) with BIRADS MRI features from the imaging report and denoted key image slice with the approximate X-Y center position if a mass was found. Key clinical features and abstracts of the pathology report including ER, PR and HER2 results and Oncotype score are included when available.
Data Access
Version 1: Updated 2011/11/09
Title | Data Type | Format | Access Points | Subjects | License | |||
---|---|---|---|---|---|---|---|---|
Images | MG, CT, MR, PT | DICOM | Download requires NBIA Data Retriever |
88 | 148 | 429 | 105,050 | CC BY 3.0 |
Clinical, pathology, radiologist reports | XLSX | CC BY 3.0 |
Additional Resources for this Dataset
The NCI Cancer Research Data Commons (CRDC) provides access to additional data and a cloud-based data science infrastructure that connects data sets with analytics tools to allow users to share, integrate, analyze, and visualize cancer research data.
- Imaging Data Commons (IDC) (Imaging Data)
Citations & Data Usage Policy
Data Citation Required: Users must abide by the TCIA Data Usage Policy and Restrictions. Attribution must include the following citation, including the Digital Object Identifier:
Data Citation |
|
Bloch, B. Nicolas, Jain, Ashali, & Jaffe, C. Carl. (2015). BREAST-DIAGNOSIS [Data set]. The Cancer Imaging Archive. http://doi.org/10.7937/K9/TCIA.2015.SDNRQXXR |
Related Publications
Publications by the Dataset Authors
The authors recommended this paper as the best source of additional information about this dataset:
No publications by dataset authors were found.
Research Community Publications
TCIA maintains a list of publications which leverage our data. If you have a manuscript you’d like to add please contact TCIA’s Helpdesk.